Paper Title :
Author : Amany ElHadary
CoAuthors : Hoda M. Amin Rashad, Mohammed H. Ismail
Source : EGYPTIAN DENTAL JOURNAL
Date of Publication : 04/2017
Abstract : Purpose: A straingauge analysis was performed to investigate the influence of interimplant distance and implant length on stress induced around mandibular overdenture implant .Materials and methods: The stresses were evaluated for three groups, group (A) two implants of length 11 mm were placed at 19, 23 and 29 mm from each other, group (B) two implants of length 13 mm were placed at 19, 23 and 29 mm from each other and group(C) two implants of length 15 mm were placed at 19, 23 and 29 mm from each other. Acrylic casts were constructed representing completely edentulous mandible. On each cast two Implants of same diameter 3.4mm were inserted, upon which complete overdentures supported by ball attachments were constructed. Strain gauges were installed in the labial, lingual and distal sides of each implant to record the strain induced by the applied loads. A special loading device used to produce standardized static vertical load of 60N . The loading positions were located at six points on the occlusal surface (second premolar, P2; first molar, M1; second molar, M2 on the right and left sides). Results: Maximum stress areas were numerically located at the the buccal sides of implants. Increasing implant length gradually from 11 mm to13 mm and to 15 mm decreased the maximum stresses around the implants. Increasing interimplant distances gradually from 19 mm to 23 mm and to 29mm increased the maximum stresses around the implants . Conclusion: interimplant distance and Implant length affect load transmitting mechanism to the alveolar bone. The results of this study suggested that the use of shorter interimplant distance and longer implant might ensure a better biomechanical environment for both implant and alveolar ridge.
Download PDF
BACK
  • Research Centers

    With the growing emphasis on collaborative and interdisciplinary science, Research Centers have become indispensable to highly ranked universities. They gain their importance from the outstanding role they play in enhancing the academic activities, in general, and post graduate reputation and scientific ranking in particular. Realizing this fact, Future University in Egypt (FUE) have decided and allocated sufficient funds and infrastructure to establish FUE Research Center (FUERC) having the following vision, mission, and goals

    read more
  • Continuing Education

    Future University in Egypt’s Department of Continuing Education (DCE) is dedicated to bridging the gap between the capabilities

    read more
  • FUE Pharmaceutical Factory

    The Future Factory for Industrial Training’s (FFIT) aim is to be recognized for its unique training facility as well as its advanced techniques. As a result, we established a training pharmaceutical plant, that provides an actual simulation of an industrial atmosphere with the processes and procedures that take place in the manufacturing world.

    read more
  • FUE Dental Hospital

    FUE has maintained a highly reputable dental faculty over the years, therefore the development of the Dental Hospital is a step towards the FUE goal of providing the best dental academic programs

    read more
Community service unit at Faculty of Pharmaceutical Sciences and Pharmaceutical Industries, launches Q&A about Covid-19.

Community service unit at Faculty of Pharmaceutical Sciences and Pharmaceutical Industries, launches Q&A about Covid-19.

COVID-19 Awareness
FUEscientificJournals

VISIT FUE

Take a step to<br>Future<br>For a better future

Copyright © 2023 [Future University in Egypt]. All rights reserved.