Author  : Mohamed Mohamed
                
                
                    CoAuthors : Y ABOUL-ENEIN, Mohammed GAMAL
                
                
                    Source : Gazi University Journal of Science
                
                
                    Date of Publication : 01/2015
                
                
                    Abstract :
                    ABSTRACT Accurate and sensitive spectrofluorimetric method was developed for 
determination of diiodohydroxyquinoline in presence of metronidazole. In this method the 
native fluorescence of diiodohydroxyquinoline in water solvent at λ= 495 nm when excitation 
was at 250 nm is used for its determination. Linear correlation was obtained in the 
concentration range of 400 to 900 ng mL-1. The proposed method was successfully applied 
for determination of diiodohydroxyquinoline in bulk powder with mean accuracy of 100.21 ...
                